The Customized configuration is the build-to-order option in our container data center family: instead of fitting a project into a catalogue size, the container, rack count, power path and cooling are specified around it. Capacity ranges from a few tens of kW up to 500 kW, with rack loads up to 20 kW+ and redundancy chosen as N+1 or 2N.
Cooling is matched to the density - in-row units inside cold/hot aisle containment for conventional racks, or liquid and immersion cooling once air stops being economical. The module is assembled and tested in the factory, ships as a standard-height ISO container by truck, rail or ship, and is commissioned on a simple concrete pad, so a bespoke facility still arrives as tested infrastructure rather than a construction project.
| Model No. | Container Size | Total Capacity | Rack Qty | Single Rack Load | UPS Configuration | Cooling |
|---|---|---|---|---|---|---|
| ICDC20 › | 20' HQ (ISO) | 54 KW | 9 Racks | Max 6 KW | 90 kVA Modular (N+1) | In-Row |
| ICDC40-A › | 40' HQ (ISO) | 24 KW | 4 Racks (Spacious) | Max 6 KW | 45 kVA Modular (N+1) | In-Row |
| ICDC40-B › | 40' HQ (ISO) | 72 KW | 12 Racks | Max 6 KW | 120 kVA Modular (N+1) | In-Row |
| Customized › | Non-Standard | Up to 500 KW | Flexible | Up to 20 KW+ | Custom Redundancy | In-Row / Liquid |
This is the customized build: instead of a fixed catalogue size, the container is configured around the project - any practical length, any rack count, and a power path from a few tens of kW up to 500 kW, with racks rated up to 20 kW+ where the payload demands it. Redundancy is chosen rather than assumed, so the UPS can be specified N+1 or 2N to match the site's criticality. The finished unit still ships as a standard-height ISO module by truck, rail or ship, so it can be lifted onto a simple concrete pad anywhere in the world.
Cooling is selected with the load: in-row units inside cold/hot aisle containment where racks stay in the single-digit kW range, or liquid and immersion cooling once a rack passes the point where air stops being economical. Because the internal layout is designed per project rather than fixed, the aisle width, containment, rack depth and cooling distribution can all be matched to the payload, and the factory tests the assembled module before it ships.
Tailored to diverse deployment scenarios—including small enterprise IT rooms, retrofitted traditional data centers and outdoor edge nodes—our modular data center solutions balance performance, cost and energy efficiency.
3-15 kW per Cabinet
All-in-one integrated cabinet design, plug-and-play deployment (1-3 days), remote intelligent monitoring. Ideal for edge endpoints like retail stores, ATMs and small enterprise IT rooms.
8-30 kW per Cabinet
Column-level prefabricated design, flexible expansion by rows, fits existing server rooms without major reconstruction. PUE 1.2-1.4, perfect for medium-density enterprise IT deployments.
15-40 kW per Cabinet
Airtight cold/hot aisle enclosure, 90%+ cold air utilization, PUE reduced to 1.2-1.3. Cost-effective upgrade for traditional open data centers to support high-density servers.
10-500 kW (20ft/40ft)
Prefabricated all-in-one container (20ft/40ft), dustproof/anti-vibration, deployable outdoors. Liquid cooling optional for AI high-density computing (PUE ≤1.1), ideal for edge & temporary computing needs.
Empowering next-generation infrastructure with superior thermal management for high-wattage computing demands.