Good price  online

products details

Created with Pixso. Home Created with Pixso. Products Created with Pixso.
Liquid Cooling Solutions
Created with Pixso. SY-RM-2000 2000 kW In-Room CDU Cold Plate Cooling Data Center 33 kW 190.78 m³/h ODM

SY-RM-2000 2000 kW In-Room CDU Cold Plate Cooling Data Center 33 kW 190.78 m³/h ODM

Brand Name: Soeteck
Model Number: SY-RM-2000
MOQ: 1 Set
Price: Negotiable
Delivery Time: 30-45 working days
Payment Terms: D/A
Detail Information
Place of Origin:
China
Certification:
CE, ISO, UL
Cooling Capacity:
2000 KW
Rated Power:
33 KW
Flow Rate:
190.78 M³/h
Design Temp (In/Out):
Pri: 35/45°C Sec: 50/40°C
Dimensions (WxDxH):
1396 X 1200 X 2245 Mm
Fluid Type:
Chilled Water
Inlet And Outlet Temp.:
35/45 ℃
Weight:
1500 Kg
Connecting Spec.:
φ159×3.0
Number Of Pumps:
2
Available Head:
≥120
Packaging Details:
Export packing
Supply Ability:
10 Sets per Month
Highlight:

2000 kW In-Room CDU

,

Cold Plate Cooling CDU

,

33 kW ODM CDU

Product Description

The SY-RM-2000 is a room-level coolant distribution unit (CDU) engineered for the largest cold-plate liquid cooling deployments. A single skid carries 2000 kW of cooling capacity, enough to serve a whole hyperscale server hall from one central point.

Its 33 kW rated power and 190.78 m³/h design flow are matched to the 35/45°C primary and 50/40°C secondary design temperatures used by modern AI and HPC facilities. Two circulation pumps and DN159 connections keep pressure drop low and leave margin for future load growth.


Product Family

Model No. Cooling Capacity Rated Power Flow Rate Design Temp (In/Out) Dimensions (WxDxH)
SY-RM-1000 › 1000 kW 18.5 kW 95.39 m³/h Pri: 35/45°C
Sec: 50/40°C
1000 x 1200 x 2200 mm
SY-RM-1350 › 1350 kW 26 kW 128.89 m³/h Pri: 35/45°C
Sec: 50/40°C
1396 x 1200 x 2245 mm
SY-RM-2000 › 2000 kW 33 kW 190.78 m³/h Pri: 35/45°C
Sec: 50/40°C
1396 x 1200 x 2245 mm

Product Features

 Data Center Distribution Coolant Distribution Unit CDU

2000 kW Cooling Capacity in One Skid

Delivering up to 2000 kW of cooling power in a single skid, the SY-RM-2000 is built for the largest hyperscale halls. Large-diameter piping (up to DN159) keeps pressure drop and pump energy low across the facility loop.


Room-Level Centralized Control

Concentrating coolant distribution in one room-level unit simplifies maintenance: water quality, filtration and pressure regulation are handled from a single point instead of being spread across in-row equipment.

Cooling System

FEATURED PRODUCTS OF liquid COOLING SOLUTIONS


Focus on the core cooling demands of high-density data center deployments, where our full range of liquid cooling products leverages advanced technological advantages to reliably safeguard continuous, efficient, and stable operation.

In-Rack / In-Row / In-Room

Intelligent CDU Series

The heart of liquid cooling. Available in Rack-mounted (50-80kW), In-Row (350-900kW), and large-scale In-Room (up to 2MW) configurations. Features N+1 redundancy and smart control. 

PUE < 1.2

Immersion Cooling Tank

Single-phase immersion technology for ultimate heat dissipation. Integrated plug-and-play design suitable for edge nodes and high-density clusters. Silent operation with PUE < 1.2.

Prefab & Modular

Prefab Liquid Cooling DC

Rapid-deployment modular data center. A turnkey solution integrating power, liquid cooling (Cold Plate or Immersion), and monitoring. Ideal for AI training and crypto mining.

High-Quality

Key Accessories

Essential components for safety and efficiency. Includes high-precision Manifolds, flexible Secondary Loops, and Quick Disconnects (QD) with leak-prevention design.

APPLICATIONS


Empowering next-generation infrastructure with superior thermal management for high-wattage computing demands.

AI Training and HPC Clusters
AI Training & HPC Clusters
High-Density Data Centers
High-Density Data Centers
Modular & Container Solutions
Modular & Container Solutions
Blockchain & Crypto Mining
Blockchain & Crypto Mining

FAQ


1. What industrial protocols are supported?
The SY-RM-2000 supports industrial-grade Modbus and SNMP protocols, ensuring seamless integration with Building Management Systems (BMS) and DCIM for centralized control.
2. How is water quality maintained?
The system includes advanced filtration and can be equipped with real-time water quality monitoring sensors. This ensures the coolant remains within specification to prevent corrosion and bacterial growth.
3. What power supply is required?
These high-capacity units typically require a 3-phase 380V/50Hz power supply to drive the powerful circulation pumps and control systems.
4. What cooling capacity does the SY-RM-2000 provide?
The SY-RM-2000 delivers 2000 kW of cooling capacity with 33 kW of rated power and a design flow of 190.78 m³/h. Primary/secondary design temperatures are 35/45°C and 50/40°C, sized for a full hyperscale cold-plate loop.
5. How does the SY-RM-2000 connect to an existing facility loop?
The unit connects through DN159 piping (159 mm OD, 3.0 mm wall) and houses two circulation pumps. It supports industrial-grade Modbus and SNMP, so flow, pressure and temperature can be supervised from the facility BMS or DCIM.

Have more questions about this product?

Contact Us Now