| Brand Name: | Soeteck |
| Model Number: | SY-DC60UD |
| MOQ: | 1 Set |
| Price: | Negotiable |
| Delivery Time: | 30-45 working days |
| Payment Terms: | D/A |
The Soeteck SY-DC60UD Chilled-Water Precision Air Conditioner is a 76.2 kW computer-room unit built for data halls that already have chilled water available. In a cabinet 925 x 990 x 1975 mm it delivers 11260 m³/h of conditioned air, so a row is cooled by a machine that fits through a service door and into the same footprint as the racks it serves.
With 44.0 kW of fan power driving EC or AC fans and no compressor inside the unit, the heat, noise and maintenance that come with DX cooling stay out of the hall. Control is local through the colour touchscreen on the front door and central through BMS integration with master/slave redundancy, while PTC heating of 6/9/12 kW and electrode humidification of 8/10/12 kg/h keep temperature and humidity in range through the winter — single or dual system, with optional RS485, extra sensors and low-temperature kits.
| Model No. | Cooling Capacity | Airflow Rate | Dimensions (W×D×H) | Weight | Rated Power |
|---|---|---|---|---|---|
| SY-SC30UD › | 38.2kW | 9230m³/h | 925×990×1975mm | 303kg | 24.0kW |
| SY-SC40UD › | 50.8kW | 9610m³/h | 925×990×1975mm | 312kg | 31.2kW |
| SY-SC50UD › | 62.8kW | 10230m³/h | 925×990×1975mm | 333kg | 37.8kW |
| SY-DC60UD › | 76.2kW | 11260m³/h | 925×990×1975mm | 352kg | 44.0kW |
| SY-DC70UD › | 89.6kW | 17100m³/h | 1675×990×1975mm | 492kg | 54.8kW |
| SY-DC80UD › | 100.4kW | 20500m³/h | 1675×990×1975mm | 502kg | 62.4kW |
| SY-DC90UD › | 113.2kW | 18700m³/h | 1675×990×1975mm | 512kg | 68.0kW |
| SY-DC100UD › | 124.0kW | 21360m³/h | 1675×990×1975mm | 522kg | 75.6kW |
| SY-DC110UD › | 137.6kW | 23300m³/h | 1825×990×1975mm | 539kg | 83.2kW |
| SY-DC120UD › | 147.2kW | 25030m³/h | 1825×990×1975mm | 553kg | 99.2kW |
| SY-DC130UD › | 159.6kW | 25960m³/h | 1825×990×1975mm | 562kg | 95.2kW |
| SY-DC140UD › | 177.2kW | 26120m³/h | 1825×990×1975mm | 585kg | 104.0kW |
| SY-DC150UD › | 184.2kW | 31680m³/h | 2500×990×1975mm | 772kg | 111.6kW |
| SY-DC160UD › | 199.8kW | 33120m³/h | 2725×990×1975mm | 792kg | 120.0kW |
| SY-DC170UD › | 208.2kW | 35460m³/h | 2725×990×1975mm | 812kg | 126.6kW |
| SY-DC180UD › | 221.4kW | 39100m³/h | 2725×990×1975mm | 822kg | 135.6kW |
| SY-DC190UD › | 233.4kW | 36010m³/h | 2725×990×1975mm | 842kg | 139.2kW |
| SY-DC200UD › | 265.8kW | 38500m³/h | 2725×990×1975mm | 852kg | 156.0kW |
The SY-DC60UD is rated at 76.2 kW with 11260 m³/h of airflow, delivered through a chilled-water coil from a cabinet only 925 mm wide and 1975 mm high. EC or AC fans move that volume with 44.0 kW of connected fan power, and because the coil is fed by facility chilled water there is no compressor inside the unit to add heat, noise or maintenance to the room.
A colour touchscreen on the front door gives local access to supply and return temperatures, fan status, alarms and setpoints, while the controller reports to a building management system so a hall full of units is managed as one group. Master/slave redundancy keeps the duty unit and its standby in step, so losing one machine does not take the row with it.
Panels come off individually, so coils, filters and fan trays are reached from the front without pulling the machine out of the row — maintenance stops at the panel that has to come off. The filtration stage keeps dust off the coil in a live data hall, and RS485 monitoring plus extra temperature sensors can be specified when the site wants more points in its own BMS.
The range spans air-cooled, water-cooled and chilled-water configurations, and this chilled-water unit can be ordered with a low-temperature kit where winters are hard. PTC heating of 6, 9 or 12 kW and electrode humidification of 8, 10 or 12 kg/h keep the room inside its envelope all year, single or dual system, with lightning protection and a large colour display available for diagnostics.
Focus on the core cooling demands of high-density data center deployments, where our full range of premium products leverages advanced technological advantages to reliably safeguard continuous, efficient, and stable operation.
7.5-300 kW
Designed for medium to large data centers, these units provide precise temperature and humidity regulation for the entire room. They utilize raised-floor or overhead delivery to ensure consistent airflow distribution and equipment stability.
5.6-90.1 kW
Positioned directly between server racks, this solution brings cooling closer to the heat source. It minimizes airflow paths to maximize efficiency, making it the ideal choice for managing hot spots and high-density computing clusters.
3.5-12.5 kW
An all-in-one solution integrated directly inside the server cabinet. This closed-loop system handles ultra-high thermal loads with maximum energy efficiency, isolating sensitive equipment from the outside room environment and noise.
1.0-4.0 kW
Compact and durable cooling designed for outdoor telecom cabinets, battery compartments, and industrial control panels. These units ensure reliable operation in harsh environments by strictly controlling internal temperatures and blocking contaminants.
Empowering next-generation infrastructure with superior thermal management for high-wattage computing demands.