Good price  online

products details

Created with Pixso. Home Created with Pixso. Products Created with Pixso.
Data Center UPS
Created with Pixso. 415V Industrial UPS Power Supply Backup 160kVA-600kVA For Data Center

415V Industrial UPS Power Supply Backup 160kVA-600kVA For Data Center

Brand Name: Soeteck
Model Number: SY-G
MOQ: 1
Price: To Be Negotiated
Delivery Time: 2-4W
Payment Terms: D/A
Detail Information
Place of Origin:
China
Certification:
CE, ISO, UL
System Capacity:
160-600kVA
Waveform:
Sine Wave Or Simulated Sine Wave
Backup Time:
5 To 60 Minutes Depending On Load
Type:
Power Backup Device
Battery Type:
Sealed Lead Acid (SLA) Or Lithium-ion
Output Voltage:
380×(1±1%)VAC Or Phase Voltage: 220×(1±1%)VAC
Communication Ports:
USB, RS-232, RS485, SNMP
Operating Temperature:
0°C To 40°C
Input Voltage:
380-415 VAC
Noise Level:
Less Than 60 DB
Packaging Details:
Cartons, Wooden boxes
Supply Ability:
10000 Piece/Pieces per Month
Highlight:

415V Industrial UPS Power Supply

,

160kVA Industrial UPS Power Supply

,

600kVA industrial ups power backup

Product Description

The Low-Frequency Industial UPS serves as a reliable core power security solution, meticulously designed for scenarios such as large-scale data centers, industrial precision equipment systems, medical critical care facilities, and enterprise core power supply networks.

Offered in a 160kVA-600kVA capacity range, this UPS caters to the high-power demands of medium-to-large scale application scenarios while avoiding unnecessary capacity redundancy. Its sturdy low-frequency tower structure is perfectly suited for professional high-power equipment rooms without the need for expensive custom rack modifications. Featuring advanced double-conversion technology, it achieves a peak efficiency of 96.5%, effectively lowering enterprise energy consumption costs. Adhering to stringent international power supply standards, it delivers long-term backup power and comprehensive protection for vital load devices.


Product Family

Model No. System Capacity Input Voltage Output Voltage Efficiency Wiring
SYG1600L33-N 160kVA / 144kW 380/400/415VAC Line Voltage: 380x (±1%) VAC or Phase Voltage: 220x (±1%) VAC 94% (With Optional Accessories); 98% (ECO mode) 3 phase + PE
SYG2000L33-N 200kVA / 180kW 380/400/415VAC Line Voltage: 380x (±1%) VAC or Phase Voltage: 220x (±1%) VAC 94% (With Optional Accessories); 98% (ECO mode) 3 phase + PE
SYG2500L33-N 250kVA / 225kW 380/400/415VAC Line Voltage: 380x (±1%) VAC or Phase Voltage: 220x (±1%) VAC 94% (With Optional Accessories); 98% (ECO mode) 3 phase + PE
SYG3000L33-N 300kVA / 270kW 380/400/415VAC Line Voltage: 380x (±1%) VAC or Phase Voltage: 220x (±1%) VAC 94% (With Optional Accessories); 98% (ECO mode) 3 phase + PE
SYG4000L33-N 400kVA / 360kW 380/400/415VAC Line Voltage: 380x (±1%) VAC or Phase Voltage: 220x (±1%) VAC 94% (With Optional Accessories); 98% (ECO mode) 3 phase + PE
SYG5000L33-N 500kVA / 450kW 380/400/415VAC Line Voltage: 380x (±1%) VAC or Phase Voltage: 220x (±1%) VAC 94% (With Optional Accessories); 98% (ECO mode) 3 phase + PE
SYG6000L33-N 600kVA / 540kW 380/400/415VAC Line Voltage: 380x (±1%) VAC or Phase Voltage: 220x (±1%) VAC 94% (With Optional Accessories); 98% (ECO mode) 3 phase + PE

Product Features

415V Industrial UPS Power Supply Backup 160kVA-600kVA For Data Center 0

High Performance Metrics

It adopts advanced IGBT rectifier technology, with THDi < 4% and input power factor up to 0.99—reducing grid harmonic interference while boosting power utilization. It supports a ±25% wide input voltage range (ideal for generators) and hits 94% efficiency (standard mode) / 98% (ECO mode); its 0.9 output power factor enhances load capacity.


Parallel Redundancy & Protection

It supports parallel redundancy for up to 8 units, maximizing system uptime. Built-in overload and short-circuit protection safeguards continuous, secure operation; its transformer-based design further minimizes harmonic interference to protect connected devices.


Premium Component Durability

90% of its components are sourced from global leading brands. Every unit undergoes rigorous 24-hour aging and performance testing before delivery, ensuring long-term reliability for high-demand scenarios like data centers and banking systems.


Intelligent Monitoring & Connectivity

Equipped with a multi-language LCD display for real-time system insights. It supports RS232/RS485 (plus optional SNMP) for remote management; its front-maintenance design enables quick, efficient servicing to cut downtime.

415V Industrial UPS Power Supply Backup 160kVA-600kVA For Data Center 1

Featured Types of UPS Series


With diverse UPS series spanning industrial-grade resilience, highly scalable modularity, and smart space-efficient designs, Soeteck delivers fully personalized, industry-leading high-availability power solutions to safeguard all critical electronics with unwavering reliability.

415V Industrial UPS Power Supply Backup 160kVA-600kVA For Data Center 2

1-60 kVA

Rack/Tower UPS

rack/tower convertible, space-saving, cost-effective, suitable for small-to-medium devices.

415V Industrial UPS Power Supply Backup 160kVA-600kVA For Data Center 3

1-600 kVA

Industrial UPS

3-phase unbalance allowed, high overload, ideal for critical industrial & healthcare scenarios.

415V Industrial UPS Power Supply Backup 160kVA-600kVA For Data Center 4

1-1200 kVA

Tower Online UPS

high-frequency, wide input range, high integration, fits small server rooms to large facilities.

415V Industrial UPS Power Supply Backup 160kVA-600kVA For Data Center 5

20-1600 kVA

Modular Online UPS

hot-swappable modules, N+X redundancy, flexible expansion for dynamic load demands.

APPLICATIONS


415V Industrial UPS Power Supply Backup 160kVA-600kVA For Data Center 6
Data Center & IDC
415V Industrial UPS Power Supply Backup 160kVA-600kVA For Data Center 7
Medical & Healthcare
415V Industrial UPS Power Supply Backup 160kVA-600kVA For Data Center 8
Industrial Automation
415V Industrial UPS Power Supply Backup 160kVA-600kVA For Data Center 9
Telecommunications

FAQ


1. How elevates transformer-based design anti-interference?
Our products cut harmonic interference drastically, securing stable power for precision semiconductor production loads.
2. What value brings IGBT rectifier with THDi<4%?
They minimize grid pollution, boost input power factor to 0.99, and reduce energy loss in dynamic power environments.
3. Can front maintenance reduce on-site service downtime?
Yes, it enables fast component access without system disassembly, fitting high-demand industrial/commercial operation needs.

Have more questions about our Power Solutions?

Contact Us Now